This site and contents herein are ©1998-2008, UltraVolt, Inc.



Products

"30A->40A" Series High Voltage Power Supply

PDF version is also available
Currently viewing page: 1 Jump to page: 1 2 3 4

Click here to request more information or to get a quote

“30A→40A” SERIES

HIGH VOLTAGE POWER SUPPLY

  • 0 to 30kV, 35kV or 40kV output
  • 4, 15, or 30 watts of output power
  • Wide input voltage range
  • Indefinite output short-circuit protection
  • Maximum Iout capability down to 0 Volts
  • Fixed-frequency, low-stored-energy design
  • Output current & voltage monitors
  • >400,000 Hr. MTBF @65°C
  • UL, cUL, IEC-60950-1, and Demko Recognized
  • GENERAL INFORMATION:
    The "30A→40A" Series regulated high-voltage DC-DC converters are an extension of the "A" Series, directly addressing the needs of the miniature PCB or chassis-mount ≥30kV application. Designed and built utilizing state-of-the-art power-conversion topology, these units feature surface-mount technology and encapsulation techniques providing high reliability and low cost.

    COMPATIBILITY:
    The Series "30A→40A" match the standard "A" Series for design methodology, wide input range, remote control, enable/disable, reference, shock & vibration.

    HIGH VOLTAGE OUTPUT:
    The "30A→40A" Series is a non-isolated unipolar converter. Positive or negative output must be specified. Output is adjustable from 0 to 30kV, 35kV or 40kV. As the output voltage is reduced towards 0, the maximum current capability remains unchanged.

    HIGH VOLTAGE OUTPUT TERMINATION:
    The "30A→40A" Series utilizes 40kV PVC wire. All flying leads are 18" and can be terminated with a variety of industry-standard connectors. Contact customer service for details.

    OUTPUT VOLTAGE MONITOR:
    The "30A→40A" Series features a 1000:1 voltage monitor. The monitor has an output impedance calibrated for use with a 10-Megohm input impedance meter. Overall accuracy is ±2.5% with a temperature coefficient of ±200 ppm per °C.

    The "30A" uses a 1.5 Gigohm/1.78 Megohm divider.
    The "35A" uses a 5 Gigohm/10 Megohm divider.
    The "40A" uses a 5 Gigohm/10 Megohm divider.

    For "30A→40A" applications requiring a different scale factor, such as a 0 to 5VDC ADC compatible design, a single, external, low-voltage resistor may be added in parallel with the output voltage monitor, to rescale its output. The voltage monitor is output on pin 9 and referenced to signal ground pin 5.

     

    OUTPUT CURRENT MONITOR:
    The "30A→40A" Series is equipped with an output current monitor. Current from the high-voltage multiplier can be monitored by reading the voltage appearing between output monitor pin 3 and signal ground pin 5. The monitor has an output impedance of >20kΩ. Internal voltage dividers create a small, linear-offset voltage. See Application Note AP- 13 for more details.

    SHIELDING:
    The "30A→40A" Series models are available with optional six-sided, wrap-around Mu-Metal Shielding. This shielding attenuates magnetic and electrostatic emissions, while shielding internal circuitry from outside noise, thereby reducing overall output ripple by as much as 25% to 50% when combined with the Ripple Stripper® filter.

    MECHANICAL:
    The "30A→40A" Series converters are in PCB mountable plastic cases requiring footprints of only 11.1 in² to 12.75 in² and volumes of only 11.7 in³ to 16.25 in³. Mounting plates and brackets are available for chassis mounting. Also available is a metal RF-tight PCB/chassis-mount package. See Application Note 6 for thermal considerations and mounting configurations. All models are available with optional "-M" six-sided, wrap-around Mu-Metal Shielding. Despite their high efficiency, the compact PCB-mounted units require the optional "-H" factory-installed heat sink or an equivalent customer-installed device in high-temperature applications.

    ENVIRONMENTAL:
    The “30A→40A” Series provides full power operation at case temperatures from -40 to +65°C. All units receive a 24- hour burn-in prior to final test. Extended temperature range is available along with other enhanced capabilities. Please contact the factory.


    1800 OCEAN AVE., FRNT
    RONKONKOMA, NY 11779

    TEL  800-9HV-POWER
    TEL  631-471-4444
    FAX  631-471-4696

    www.ultravolt.com

    next page

    © 2003-2008 UltraVolt, Inc.
    Specifications subject to change without notice.


    UltraVolt, Inc.
    1800 Ocean Ave. Frnt
    Ronkonkoma, NY 11779
    1-800-9HV-POWER
    1-800-948-7693
    631-471-4444
    Fax: 631-471-4696
    E-mail: csd@ultravolt.com